Online Use of SIGNOFF
Online, SIGNOFF does not transfer control to CA IDMS/DC, DC/UCF, or the transfer control facility; the [Clear] key or the top-line command, [Clear], must follow SIGNOFF in order for the compiler to relinquish control.
When SIGNOFF is Not Required
SIGNOFF is recommended as the best way to terminate a compiler session. However, SIGNOFF is not always required, as described next:
DDL Compilers Ignore Statements Following SIGNOFF
Any statements following the SIGNOFF command are ignored by the DDL compilers. In the following example, SIGNON and ADD SCHEMA are ignored. To end this session and begin another, eliminating the SIGNOFF statement would produce the desired results.
signoff. signon dictionary=otherdd. add schema name is othrschm.
|