Using CULLUS48

Status or diagnostic messages can be added to the run-time message chapter of a CA Culprit job by using the CULLUS48 user module. A message containing up to 132 characters can be executed in type 7 logic, as follows:

010 MESSAGE '0 THIS IS A MESSAGE  %%'
 .
 .
 .
927  CALL US48 (MESSAGE)

Note: The message, an alphanumeric string placed within single quotation marks, must start with a carriage control character and end with two percent signs.

More information about CULLUS48 can be found in CA Culprit for CA IDMS User Modules Guide.