CA Culprit prints a Sequential Parameter Listing after errors occur when trying to access a table specified on the INPUT parameter. The following report shows an example:
mm/dd/yy SEQUENTIAL PARAMETER LISTING volser Vnn.n PAGE 1 00 ** SYSIN ** DATABASE DICTNAME=ASFDICT PROFILE USER=DOC2 PW= C200138 INSTALLATION SECURITY OPTION IS NO INPUT TABLE=ACCOUNTING W C200074 KEYWORD EXPECTED - TYPE= (CONT) CULPRIT WILL SUBSTITUTE TYPE=COPY E C700020 IDB GET TABLE ERROR DC551040 (E) CATALOG ERROR: TABLE WAS NOT FOUND ┌────────────────────────┐ (CONT) │RSUB RETURN CODE: 0040 │ RSUB and TDB code CA Culprit (CONT) │TDB MINOR CODE: 002 ◄------------------------------------------------- prints after attempting to └────────────────────────┘ access table ACCOUNTING. W C700048 CULPRIT IS UNABLE TO GENERATE A PATH CARD. DATA DICTIONARY LOOKUP IS ALSO SUPPRESSED, AND THIS WILL BE THE CAUSE OF OTHER ERRORS 0151*001 DEPT-NAME 0151*002 EMP-ID 0151*003 EMP-NAME F C200229 PATH PARAMETER IS REQUIRED
|