The CA Gen runtime modules must be available to the target CICS region as part of the CICS DFHRPL data set concatenation. Add the CA Gen 8.5 runtime DLL library, CEHBPLD1 to the data set concatenation or copy the relevant modules to a library in the concatenation. The data set that contains the CA Gen runtime modules must be a data set of type LIBRARY, a PDSE.
DLLs required for all types of generated CICS applications are TIRORUNC, TIRMTQBZ, TIRTERAZ, TIRARUNC, TIRSDTNZ, TIRCDPTZ, TIRCRTRZ, TIRCSYSZ, TIRCTIAZ, TIRCURTZ, TIRCUSRZ, TIRDATXZ, TIRDEVCZ, TIRDLCTZ, TIRHELPZ, TIRQCNTZ, TIRSECRZ, TIRUPPRZ, TIRYYXZ, TIRRTLDC and TIRMMDLL.
DLLs required for generated CICS Block Mode Enhanced Map applications are TIRCGSPZ, TIRCHPZ, TIRCHPRZ, TIRCIIMZ, TIRCO2PZ, TIRCO2SZ, TIRCPINZ, TIRCPUIZ, TIRCVINZ and TIRIEXZ. The TIRIEXSZ DLL is required for generated CICS Block Mode Standard Map applications.
DLL TIRCRUNC is required for generated CICS server applications and CICS block mode applications being traced. DLLs required for generated CICS server applications are TIRCALLZ, TIRCROUZ, TIRNCRYZ, TIRDCRYZ, TIRELOGZ, TIRPTOKZ, TIRCSGNZ, TIRSECVZ, TIRSIPEZ, TIRSRTRZ, TIRSURTZ and TIRXINFZ. In addition applications targeting Websphere MQSeries require TIRMQPXZ and either TIRCMQC or the TIRMQTDC DLL depending on which CICS MQSeries method they use. See Customize for MQSeries in this section.
Each module must have a corresponding CICS program definition that can be added to CICS using the CA Gen supplied DEFCICS job, or by using the CICS Resource Definition Online (RDO) mechanism, for example, the CICS CEDA transaction. If using RDO, see DEFCICS job for information about defining each copied module.
To re-load a new copy of a CA Gen runtime module, log on to CICS and execute the following CICS command:
CEMT SET PROGRAM(module name) NEW
|