Previous Topic: Default BehaviorNext Topic: Related User Exits


Building the Exit

The CI_CM_DPC_Flow_Complete_Comm_Error exit is built as a part of the dynamic link library CMICXxxN.DLL.

Note: xx refers to the current release of CA Gen. For the current release number, see the Release Notes. N indicates platform.

A prerequisite for building the DLL, you must have Microsoft’s Visual C++ compiler installed on your system.

Follow these steps:

  1. Launch a Command Prompt window.
  2. Change your current directory to that directory which contains the makefile CCMEXIT.NT (%GENxx%Gen\VSabc for Visual Studio 32-bit or %GENxx%Gen\VSabc\amd64 for Visual Studio 64-bit).

    Note: VSabc refers to the supported version of Visual Studio. Replace VSabc with VS100 for Visual Studio 2010 and VS110 for Visual Studio 2012. xx refers to the current release of CA Gen. For the current release number, see the Release Notes.

  3. Set Microsoft Visual Studio compiler environment variables.
  4. Run NMAKE /F CCMEXIT.NT CLEAN.
  5. Run NMAKE /F CCMEXIT.NT.
  6. Copy the CMICXxxN.DLL user exit into the Client Manager’s install directory.