Previous Topic: CGB0019S – Bounds error processing field <field_name} during forced placement of TRANCODE, PANELID, or FMI.Next Topic: CGB0021S – Illegal or unknown field type for edit pattern synthesis.


CGB0020S – Unable to force placement of <field_name> field.

Reason:

During phase 1, metamodel transformation post processing, the generator attempted to place the TRANCODE, PANELID, LINKACTIVE, or FMI fields. The generator attempted to force place the missing fields, and there is no usable area on the screen.

The generator terminated without changing or creating source files.

Action:

Remove fields, literals, or prompts, or rearrange the screen, to create free space for the fields, or place the transaction code or the panel ID fields. The generator always force places the FMI field when targeting MFS. You cannot explicitly place it.