This section details messages generated in the course of processing, along with possible causes and corrective actions to take in error situations.
Reason:
The standalone COMPARE utility has rejected a PDM COMPARE operation.
Action:
For more information, check the BSTPCOMP return codes listed in the Utilities Guide.
Reason:
PDM was unable to obtain sufficient virtual storage to perform the requested function. Either a region specification on a job statement was too small, or a TSO logon region size was insufficient.
Action:
If the error occurred during background operation, increase the region size requested on the job statement. If the error occurred in foreground, log on to TSO with a bigger region size.
Reason:
An input to the Build WIP process was not located. The member or Element specified for [INPUT] location was not found in that location.
Action:
Check that the PDM input syntax language specified the information location correctly. If the problem persists, verify that the CA Endevor SCM location exists.
|
Copyright © 2015 CA Technologies.