Previous Topic: System Parameter ConsiderationsNext Topic: XCOPY Commands and Parameters


Simulate Mode Considerations

By using the SET MODE=SIMULATE command in an XCOPY job, CA Disk instructs XCOPY to execute without actually mounting any ARCHVOLS or copying any DSNINDEX records. The result is a report indicating which DSNINDEX and ARCHVOL records would have been selected in a live run.

Because output devices are not allocated during simulations, CA Disk cannot accurately predict the number of output ARCHVOLS there will be in a live run. If you only want to know which DSNINDEX and/or ARCHVOL records will be selected for input by XCOPY, then this is not a concern. However, certain steps need to be taken if your intent is to determine the approximate number of ARCHVOLS that will be required for output.

XCOPY has a facility to simulate specific device types to predict volume capacity, and when a volume switch would occur. This is accomplished by specifying the appropriate DYNnUNIT/DYnnUNIT sysparm with the CA Disk value for the device type to be simulated as indicated below:

The MERP1TYP (MERC1TYP and/or MERT1TYP, if desired) sysparm should specify one of the following Media Option types:

Media Option

Sysparm in Effect

3480

DYNCUNIT

DYN1

DYN1UNIT

DYN2

DYN2UNIT

DYN3

DYN3UNIT

DYN4

DYN4UNIT

DYN5

DYN5UNIT

DYN6

DYN6UNIT

DYN7

DYN7UNIT

DYN8

DYN8UNIT

DYN9

DYN9UNIT

DY10

DY10UNIT

DY11

DY11UNIT

DY12

DY12UNIT

DY13

DY13UNIT

DY14

DY14UNIT

DY15

DY15UNIT

DY16

DY16UNIT

DY17

DY17UNIT

DY18

DY18UNIT

DY19

DY19UNIT

DY20

DY20UNIT

The DYNnUNIT/DYnnUNIT sysparm, related to the previous Media Options, should be specified with one of the following cartridge device types:

Value

Device Simulated

Capacity

01600

3420 at 1600 BPI

 

06250

3420 at 6250 BPI

 

34800

3480 Standard

208 MB

34801

3480 Enhanced

396 MB

34900

3490 Standard

396 MB

34901

3490/Enhanced

810 MB

34902

3490/E

1.6 GB

34903

3490/E

9.5 GB

34904

3490/E

20 GB

34905

3490/E

39 GB

34906

3490/E

60 GB

34907

3490/E

200 GB

34909

3490/E

2.0 GB

34990

Redwood Cartridge

9.5 GB

34991

Redwood Cartridge

24 GB

34992

Redwood Cartridge

47 GB

35900

3590 Magstar Cartridge

9.5 GB

35901

3590 Magstar Cartridge

19 GB

35902

3590/E

30 GB

35903

3590/E

39 GB

35904

3590/E

60 GB

3590C

3590/E

75 GB

35907

3590/E

100 GB

35908

3590/E

120 GB

35905

3590/E

200 GB

3590D

3590/E

240 GB

35906

3590/E

300 GB

35909

3590/E

500 GB

3590A

3590/E

700 GB

3590B

3590/E

1000 GB

Note: The simulated devices represented in this table will only work when sysparm CARTCALC is specified with a value of Y. If CARTCALC is set to N, all 3480/3490 devices use CARTFEET. For more information, see the sysparm descriptions of CARTCALC, CARTPRCT, and CARTFEET in the Systems Guide.

To specify a unit address using the DYNnUNIT or DYnnUNIT sysparm, it must be preceded by an EBCDIC slash(/).

For example, to direct the duplex copy of an XCOPY ARCHVOL to a 25 GB Redwood cartridge device, specify:

//SYSPARMS DD *
MERP1TYP3480
MERC1TYPDYN1
DYN1UNIT34991