Only one SELECT command per execution is allowed.
//SMFDATA EXEC SMFRPT //SYSIN DD * SELECT COUNT=,DSN=,START=,STOP=,CLOSE,TAPE
The maximum number of SMF records to be read in this execution, specified as a 1- to 10-digit number between 1 and 2147483647. SMF records past this number will be bypassed. If not specified, this parameter will default to 10000000.
A list of one or more data set names or patterns for which a report is desired. Omission of the parameter results in SMF records for all data set names being selected. (A maximum of 50 entries is supported.)
The date in an accepted CA Disk format for which reporting is to begin. Records with a start date earlier than this date will be bypassed.
The date in an accepted CA Disk format for which reporting is to terminate. Records with a close date later than this date will be bypassed.
The presence of this simple parameter causes the start date to be set equal to the stop (SMF CLOSE) date. Otherwise, the start date is obtained from the reader time stamp field in the SMF type 14 or 15 record.
The presence of this parameter results in tape data sets being included in the report. The volume serial number field is be filled with blanks for all tape records.
The generation and version numbers will be reset to zero for all GDG data sets.
|