2571

CALCULATED DATA CI RBA POINTER IS GREATER THAN THE HIGH ALLOCATED RBA FOR THE DATA COMPONENT. CALCULATED RBA = (nnn)

Reason:

A data control interval address, which was calculated by CADisk, was out of the range of the data component. The control interval address is calculated by adding the control area's base RBA (CDKRCICA) to the product of the data control interval size and the relative data control interval in the control area (CDKRCICA). This error stops all processing for the cluster.

Action:

Attempt to read the data set using VSAM logical access. This can be accomplished by either rerunning the CADisk job with sysparm VSACCESS specified with a value of L (check CADisk user exit VSACESEX too), or by printing the data set with the IDCAMS PRINT utility. If the data set can be accessed by logical access, contact CA Technical Support for assistance.