Previous Topic: Create A New Slot for the Certificates

Next Topic: Generate the Certificate Authority Key Pair

Test the New Slot

To test the new slot

  1. Query the status of the slot using the following command:
    ctstat -sslot-number
    

    This produces output similar to this:

    ProtectToolkit C Status Utility $Revision: 1.32 $
    Copyright (c) Eracom Technologies 2003
    Slot ID 2
        Description      : CSA8000:53551
        Manufacturer     : ERACOM Pty. Ltd.
        Hardware Version : 71.00
        Firmware Version : 1.42
    Token for Slot ID 2
        Label            :
        Manufacturer     : ERACOM Pty. Ltd.
        Model            : 8000:PL450
        Serial Number    : 4133:53551
        Hardware Version : 71.00
        Firmware Version : 1.42
    
  2. Look for the following message:
    ctcert: The token in slot # is not initialised.
    

    If you see it, run the following command:

    ctconf -nslot-number
    
  3. Look for the following message:
    ctcert: The user PINN for the token in slot # is not initialised.
    

    If you see it, run the following command:

    ctkmu p -sslot-number