After completing your entries on the Selection Criteria Fill-in panel for the UPDATE FIELD option with RECORD or TABLE entity-type specified, press Enter. If there are no errors, CA Datacom Datadictionary displays a FILE Maintenance Panel similar to the following panel.
Note: Access to this panel is not allowed for occurrences in PROD status. You can also update occurrences in PROD status using batch transactions. For more information, see the CA Datacom Datadictionary Batch Reference Guide.
For illustration, the following example is for a TABLE entity. The table containing the fields you define can be accessed by SQL applications if the fields you define meet the conditions noted in this section.
=> => => -------------------------------------------------------------------------------- DDOL: ANCHORED OCCURRENCE FOR TABLE FIELD MAINTENANCE TYPE OCCURRENCE STA VER TBL ACCTS-REC T 001 ------------------------------------------------------------------ -------T03U Level Field-Name DB Element-Name Preci Type Len Repeat Just Rdf Null Fill (Num:Sign Type Dec) ====== == ======== ================== T O P ======= ===== ==================== 000001 1 ORD-ID 00000 N 00005 00001 R N N Y C 000 000002 1 BILL-DT 00000 C 00006 00001 L N N N C 000 000003 2 BILL-YR 00000 C 00002 00001 L N N N C 000 000004 2 BILL-MO 00000 C 00002 00001 L N N N C 000 PF1=HELP PF2=END PF3=CLARIFY PF4=PROCESS PF5=MENU PF6=STATUS MORE.... PF7=SCB PF8=SCF PF9=APPLY PF10=PATH PF11=NEXT PF12=INPUT
If the display is longer than the screen, you can use the scroll commands or PF keys to move backwards and forwards through the display. Another panel to display the additional fields follows the description of the fields on this panel.
If FIELD occurrences have not been defined to the table or record, CA Datacom Datadictionary displays the above panel with only one line. Specify the attribute-values using the following descriptions and use the steps below to insert additional lines.
If FIELD occurrences have been defined to the table or record, you receive a FILE Maintenance Panel similar to the above panel. If the list of fields extends beyond the bottom of your screen, you can use the scroll functions to locate the desired FIELD occurrences in the display.
After completing your entries on the FILE Maintenance Panel, press PF9 (APPLY). If there are no errors, CA Datacom Datadictionary displays the Field Summary Display panel with the message confirming successful field maintenance. The Field Summary Display panel lists the FIELD occurrences, the attribute-values you specified and the attribute-values you allowed to default.
If an entry for a field is incorrect, you receive an error code in the column to the left of Level on the FILE Maintenance Panel when you press PF9 (APPLY). For more information about field maintenance error codes, see the CA Datacom/DB Message Reference Guide.
|
Copyright © 2014 CA.
All rights reserved.
|
|