Previous Topic: Processing NotesNext Topic: Execution Requirements for DL/I (z/OS)


Communications Area Use

In addition to the control information you specified in bytes 1—255 of the I/O area, the Reporting Facility automatically sets up an 80-byte Communications Area. This Communications Area returns the PCB information on completion of a GET command.

Information returned to the Reporting Facility by the 80-byte Communications Area has the following format:

Field Name

Position

Description

PCBPROPT

1—4

Processing option

PCBSC

5—6

Status code

PCBDBDNM

7—14

Database name

PCBLEV

15—16

Segment level feedback

PCBSEGNM

17—24

Segment name feedback

PCBLFBK

25—28

Length of key feedback area (fullword binary)

PCBFBK

29—30

Key feedback area

Use the area with the return code from the GET command to determine the status of the I/O area. Reference the 80-byte Communications Area by the keyword DL1 and reference the return code by the file name.