Previous Topic: DB18003ENext Topic: DB18007C


DB18006C

CRITICAL RESTART ERROR - nn

Reason:

A fatal error occurred during the restart portion of the Multi-User Facility enable. The restart process continues as best as possible to completion at which point this message is recorded. The various possible values of nn are:

01

Running as a MUFplex and enabling as a non-first Multi-User Facility, but the Log Area (LXX) is not marked as open. It is not possible for this to be correct. Some possible conditions that could cause this:

02

Running as a MUFplex, and this or another Multi-User Facility is trying to run, or running with more tasks than specified as the maximum tasks in the MUFplex.

03

A fully spilled task has been found in the Log Area (LXX) that indicates a MUFplex number larger than 7.

04

A fully spilled task has been found, indicating a Multi-User Facility within the MUFplex that is not considered enabled nor down from a hard failure.

05

A fully spilled task has been found for a higher task number than is currently available. Enlarge the number of tasks to that which was used before.

06

An invalid log record has been found with a MUFplex number that is invalid.

08

An internal error occurred. Contact CA Support. For information about contacting CA Supportt, see Troubleshooting.

10

Running as a MUFplex, not first Multi-User Facility enabled, and cannot find the TSN record in the Coupling Facility.

11

Either the C Runtime component is missing or the MUF SQL component could not initialize because the MUF region size is too small or another error occurred stopping the MUF SQL component from proper initialization.

12

Running as a MUFplex and found a task record in the Coupling Facility that should not be there.

Action:

Correct all errors, then enable the Multi-User Facility again.