Reason:
An I/O error occurred writing a block to the Statistics and Diagnostics Area (PXX). The Multi-User Facility ignores the error and continues writing to the PXX past the error location. After five DB01004E messages, additional messages are not produced and the Multi-User Facility can continue writing to the PXX while ignoring the I/O errors.
The success of the DBUTLTY REPORT AREA=PXX function is dependent on the specific nature of the hardware or software condition causing the I/O error. It is possible for the REPORT functions to read past the point of the I/O error. However, the report may have missing data and show no indication of the missing data.
Action:
Attempt to determine, by using operating system or hardware tools, if it was a hardware error. If so, take the appropriate action. If it was not a hardware error, contact CA Support. For information about contacting CA Support, see Troubleshooting.
|
Copyright © 2014 CA.
All rights reserved.
|
|