AutoCollect - Creating User Defined DELTA Rowsets › Manipulating Delta Rowsets - User Created Delta Rowsets › Executing AUTOCOLL OPTION=BASELINE/SUMMARY/AVGPERF
Executing AUTOCOLL OPTION=BASELINE/SUMMARY/AVGPERF
When executing the AUTOCOLL function, the STEPLIB concatenation must include the following:
- Library with the DBSIDPR module that points to the repository MUF, that is, the MUF that contains DBID 1019 and 1020
- Complete set of CA Datacom execution libraries
The AUTOCOLL function performs the following:
- Use a standard URT to connect to the repository MUF through DBSIDPR
- Open the Delta database
- Process the Delta rowsets selected by the input parameters
- Generate a new Delta rowset
- Produce a report providing
- Delta rows read in and processed
- Output duplicate Delta rowset that was ignored
- Output Delta rows that had errors and were not written
- Error listing with detailed information about error rows
Copyright © 2014 CA.
All rights reserved.
 
|
|