Previous Topic: Example JCL (FBA)Next Topic: Type H - Utility Function History Report


Sample Report: REPORT DEVICE (FBA)

Date: mm/dd/ccyy ******************************************************************************** Page: 1 * CA Datacom/DB * Time: hh.mm.ss * General Utility * Release: 12 * Copyright © 2009 CA. All rights reserved. * SPnn ******************************************************************************** CONTROL CARD(S) .........1.........2.........3.........4.........5.........6.........7.........8 Œ REPORT DEVICE=FBA,RECSIZE=2048,COMPER=25,COMPRESS=YES, GROWTH=25,RECORDS=250000,RECOVERY=YES FUNCTION=REPORT  COMPER=25 COMPRESS=YES DEVICE=FBA GROWTH=025 RECORDS=00250000 RECOVERY=YES RECSIZE=02048 Ž

Œ

The command exactly as entered.



An analysis of keywords encountered and expected. Any errors found are flagged with a note in the left margin.

Ž

Any messages related to syntax processing are presented in this area.

Date: mm/dd/ccyy ******************************************************************************** Page: 2 * CA Datacom/DB * Time: hh.mm.ss * General Utility * Release: 12 * Copyright © 2009 CA. All rights reserved. * SPnn ******************************************************************************** MATRIX FOR DEVICE TYPE....."FBA ". { ------------------------------------------------------------- { # 50176 # 49664 # 49152 # 48640 # 48128 # { #-----------#-----------#-----------#-----------#-----------# { # 47616 # 47104 # 46592 # 46080 # 45568 # { #-----------#-----------#-----------#-----------#-----------# { # 45056 # 44544 # 44032 # 43520 # 43008 # { #-----------#-----------#-----------#-----------#-----------# { # 42496 # 41984 # 41472 # 40960 # 40448 # { #-----------#-----------#-----------#-----------#-----------# { # 39936 # 39424 # 38912 # 38400 # 37888 # { #-----------#-----------#-----------#-----------#-----------# { # 37376 # 36864 # 36352 # 35840 # 35328 # { #-----------#-----------#-----------#-----------#-----------# { # 34816 # 34304 # 33792 # 33280 # 32768 # { #-----------#-----------#-----------#-----------#-----------# { # 32256 # 31744 # 31232 # 30720 # 30208 # { #-----------#-----------#-----------#-----------#-----------# { # 29696 # 29184 # 28672 # 28160 # 27648 # { #-----------#-----------#-----------#-----------#-----------# { # 27136 # 26624 # 26112 # 25600 # 25088 # { #-----------#-----------#-----------#-----------#-----------#  { # 24576 # 24064 # 23552 # 23040 # 22528 # { #-----------#-----------#-----------#-----------#-----------# { # 22016 # 21504 # 20992 # 20480 # 19968 # { #-----------#-----------#-----------#-----------#-----------# { # 19456 # 18944 # 18432 # 17920 # 17408 # { #-----------#-----------#-----------#-----------#-----------# { # 16896 # 16384 # 15872 # 15360 # 14848 # { #-----------#-----------#-----------#-----------#-----------# { # 14336 # 13824 # 13312 # 12800 # 12288 # { #-----------#-----------#-----------#-----------#-----------# { # 11776 # 11264 # 10752 # 10240 # 9728 # { #-----------#-----------#-----------#-----------#-----------# { # 9216 # 8704 # 8192 # 7680 # 7168 # { #-----------#-----------#-----------#-----------#-----------# { # 6656 # 6144 # 5632 # 5120 # 4608 # { #-----------#-----------#-----------#-----------#-----------# { # 4096 # 3584 # 3072 # 2560 # 2048 # { #-----------#-----------#-----------#-----------#-----------# { # 1536 # 1024 # 512 # 0 # 0 # { #-----------#-----------#-----------#-----------#-----------#



Matrix of blocksizes for different blocks per track. The first row shows block sizes for one through five blocks per track. The second row shows six through ten blocks per track, and so forth.

Date: mm/dd/ccyy ******************************************************************************** Page: 3 * CA Datacom/DB * Time: hh.mm.ss * General Utility * Release: 12 * Copyright © 2009 CA. All rights reserved. * SPnn ******************************************************************************** --------------------------------------------------------------------------- # DEVICE # RECORD # RECOVERY # COMPRESSION # FIRST # RECORD # GROWTH # } # TYPE # SIZE # Y/N # Y/N # PERCENT # R P B # QUANTITY # PERCENT # } #--------#--------#----------#-----#---------#-------#----------#---------# }  # FBA # 2048 # Y # Y # 25 % # 0 # 250000 # 25 % # } --------------------------------------------------------------------------- ----------------------------------------------------------------------- # RCD # MINM # DEVICE # FBA BLOCKS # DATA SPACE REQUIRED ## } # PER # BLOCK # BLOCK # REQUIRED PER # PRIMARY # GROWTH # TOTAL ## } # BLK # SIZE # SIZE # PHYSICAL BLK # BLOCK # BLOCK # BLOCK ## } #-----#-------#--------#---------------#---------#---------#---------## } # 1 # 1559 # 2048 # 4 # 250000 # 62500 # 312500 ## } # 2 # 3116 # 3584 # 7 # 125000 # 31250 # 156250 ## } # 3 # 4673 # 5120 # 10 # 83334 # 20834 # 104168 ## } # 4 # 6230 # 6656 # 13 # 62500 # 15625 # 78125 ## } # 5 # 7787 # 8192 # 16 # 50000 # 12500 # 62500 ## } # 6 # 9344 # 9728 # 19 # 41667 # 10417 # 52084 ## } # 7 # 10901 # 11264 # 22 # 35715 # 8929 # 44644 ## } # 8 # 12458 # 12800 # 25 # 31250 # 7813 # 39063 ## } # 9 # 14015 # 14336 # 28 # 27778 # 6945 # 34723 ## } # 10 # 15572 # 15872 # 31 # 25000 # 6250 # 31250 ## } # 11 # 17129 # 17408 # 34 # 22728 # 5682 # 28410 ## } # 12 # 18686 # 18944 # 37 # 20834 # 5209 # 26043 ## } # 13 # 20243 # 20480 # 40 # 19231 # 4808 # 24039 ## } . . . . . . . } . . . . . . . . . . . . . .



Displays the parameters you coded with the REPORT DEVICE option. The report also displays the default values for parameters not coded.

This table provides you with the information you need to determine optimum device block size. Use TOTAL BLOCK under the DATA SPACE REQUIRED column, locate the lowest value or the least amount of space to allocate. Read across the report to determine the DEVICE BLOCK SIZE. Other information is provided on the report which can be useful in making space allocation decisions or in determining whether to rerun the report with different parameter values.

Important! The MEMORY=CF report is provided for use by Technical Support and should only be executed if requested by them. They are able to interpret the results as necessary. No report is possible against the lock structure.