INIT CXX/FXX/IXX/LXX/Data Area › INIT Data Area (Format Data Area) › Successful Execution Requirements and Controls
Successful Execution Requirements and Controls
Environmental Requirements when MULTUSE=NO
- The database may not be open for update anywhere.
- The database may not be open in any Multi-User Facility for read.
- The database may not have any table in unloading status.
Environmental Controls when MULTUSE=NO
- The database will be opened for update.
- The utility has no knowledge about current ACCESS database or area status.
- The utility sets no ACCESS database or area status.
Environmental Requirements when MULTUSE=YES
- The database may or may not be open for update in the connected Multi-User Facility.
- The database may not be open for update in another Multi-User Facility or Single User job.
- The database may not have any table in unloading status.
- The database ACCESS must be set OPTIMIZE and WRITE/UTLTY.
- The area ACCESS must be set WRITE/UTLTY.
- The area may have no table in an open User Requirements Table.
- The area may not have any other MULTUSE=YES utility executing.
- The area must be closed.
Environmental Controls when MULTUSE=YES
- The database will be opened by Multi-User Facility for update.
- The utility sets ACCESS area OFF (utility set).
- The utility sets INIT executing this Multi-User Facility this database or area.
Copyright © 2015 CA Technologies.
All rights reserved.
 
|
|