Processing, DBUTLTY and SQL Messages › CA Datacom/DB Messages for Invocation of CAIRIM (DB9xxxxc) › DB90152E
DB90152E
DATACOM PARM SYNTAX ERROR (x)
Reason:
CAIRIM is being used to install the Datacom PC functions or clear a control block and the message indicates an error has occurred processing the input parameters. The various errors that are possible each have a letter assigned and it is provided in the parenthesis in place of the 'x'.
Action:
Some errors are because an invalid syntax was specified for the input PARM data and those can be easily corrected and the step reissued. Other errors require opening a CA Support issue for CA Datacom that uses the information provided to resolve the issue.
The PARM values are documented fully within the CA Datacom Database System and Administration Guide. Samples of expected PARM values are as follows:
PARM(PC=PROD,PCC=DBPCCPR)
PARM(PC=PROD,PCS=DBPCSPR)
PARM(PC=TEST,PCC=DBPCCPR)
PARM(PC=TEST,PCS=DBPCSPR)
PARM(NEW=AC)
The specific error letters are:
- A - The PARM value starts with PC=PROD, or PC=TEST, but is not followed by PCC= or PCS=.
- B - The PARM value starts with PC= but is not followed by either PROD or TEST.
- C - The PARM value does not start with PC= or NEW=AC.
- D - See the preceding DB90155E message and pursue its action.
- E - The DB_SVC_AC memory could not be found or built. Collect this documentation and DBUTLTY REPORT MEMORY=MVS,DUMPS=FULL and contact CA Support.
- F - The DB_SVC_AC memory could not be found or built. Collect this documentation and DBUTLTY REPORT MEMORY=MVS,DUMPS=FULL and contact CA Support.
- G - The module named after PCC=or PCS= could not be loaded from the load library pointed to by the CAIRIM input option: LOADLIB(dsn). You must copy the current member into the named library or point to the library containing the version of the program you are intending to install.
- H - The module named after PCC= or PCS= has been loaded but is not the proper module. It does not contain the expected code. It could be for the wrong version.
- I - The current CA Common Services does not seem to have been installed. Collect documentation and contact CA Support.
- J - The current CA Common Services does not seem to have been installed. Collect documentation and contact CA Support.
- K - An internal error has occurred installing the DB_SRV_AC control block.
- L - Insufficient 31-bit memory exists to install the DB_SVC_AC control block.
- M - The current CA Common Services does not seem to have been installed. Collect documentation and contact CA Support.
- N - The current CA Common Services does not seem to have been installed. Collect documentation and contact CA Support.
- O - The DB_SVC_AC memory could not be found or built. Collect this documentation and DBUTLTY REPORT MEMORY=MVS,DUMPS=FULL and contact CA Support.
Copyright © 2015 CA Technologies.
All rights reserved.
 
|
|