Use the INIT LXX option to build a new Log Area when creating a new MUF. The Log Area cannot be shared by multiple MUFs. An INIT of the LXX should be a one time occurrence in that version of CA Datacom/DB. If there is ever a need to clear the LXX(LOG), we recommend you perform a DBUTLTY function RESET on the LXX. This clearing of the LXX should never be attempted on a production or development MUF without specific direction from CA Support.
You must format the Log Area with the INIT function before it can be used by CA Datacom/DB. Do not attempt to process a table before completing this function.
The LXX should never be initialized when it is in use. In Simplify mode, edits protect this requirement in several ways. This function may not execute with the MUF enabled in Simplify mode, and control is established over the CXX to execute without MUF. It may not follow any other functions that use MUF, and none may follow. The function may not follow any function causing the LXX to be opened. To provide better 24x7 support, an exception to some protections exist to allow for a requirement to initialize a new LXX data set intended to replace the current one during a MUF short time outage. The new LXX would have to have a new data set name that would be renamed to the proper name during the MUF outage. To request this special requirement, the INIT AREA=LXX must follow a function of SET OPTION1=SIMPLIFY_BYPASS_EDITS_1.
|