Previous Topic: FTP File Transfers Fail to CompleteNext Topic: Automated NBA RPM Package Install Process Stalls


NBA Console Fails to Load

Symptom:

I have changed the speed or duplex settings of the Bivio 7000 management port. Now the NBA console fails to load. The network connection to the mgt0 interface does not respond.

Solution:

Setting a port at the wrong speed or duplex results in connection problems. Set the Bivio appliance to the same speed and duplex as the other end of the cable. If the other end is set to auto-negotiate, the appliance can lock up if you connect with a set speed; in this case, also set mgt0 to auto.

  1. Log on to the Bivio as "admin" using the serial port.
  2. Enter the following commands:
    configure interfaces
    set interface <interface> speed [TH]<auto|10|100|1000> duplex <full|half>
    commit boot
    

    The connection is restored.

More information:

If Bypass Relay Is Closed