Previous Topic: How Is It Protected?Next Topic: Accessor Elements


Class Activation

CA ControlMinder stores information about whether a CLASS is active or inactive in the database. When CA ControlMinder starts, it passes a list of active classes to SEOS_syscall, so CA ControlMinder does not have to constantly intercept these classes. The only time CA ControlMinder intercepts a class is when a user changes the activity status of a class. If a class is inactive, access to the resource is not intercepted.

You can use the inactive class bypass with the following classes: FILE, HOST, TCP, CONNECT, and PROCESS.