The VAXconsole for these systems is the MicroVAX II system.
Connect the Console Manager host to a VAX 8830/8840 system by the central terminal line of a VAXconsole MicroVAX II. The central terminal line is the 25-pin TTA2: port located on the back of the VAXconsole pedestal system box. See the VAX 8840/8830 Console User's Guide for more information about the VAXconsole central terminal line.
Important! If Console Manager is connected to the OPA0: local console port, the POWER command could accidentally be entered through a remote Console Manager user interface while an engineer is working on the VAX 8830/8840 system.

The following VAXconsole command may only be entered at the OPA0: local console port.

Caution! Powering off the Console Manager host system or the terminal server causes random electrical signals that may resemble break signals generated on terminal lines. These signals can have a similar effect to the line disruption caused by powering off a console terminal.
The inside panel of an HSC cabinet contains a switch with two positions, SECURE and ENABLE. Set this switch to the SECURE position.
Caution! Powering off the Console Manager host system before ensuring that the SECURE/ENABLE switch on each HSC cabinet has been set correctly causes HSCs with incorrect switch settings to cease normal processing.
For each VAX 8830/8840 serviced system, perform these steps at the VAXconsole local terminal keyboard
PS-HW-0> ENABLE CENTRAL CONSOLE
PS-HW-0> SET TERMINAL PROGRAM
The VAXconsole remote port has now been successfully set up.
|