CAS9 Messages › CAS9140E
CAS9140E
Init error: 'prod' Ver 'ppvv', 'err'
Reason:
An error has occurred while attempting to initialize the named product. 'err' contains one of the following as the error description:
- Parameter error—Invalid parameters were specified for the product.
- Already initialized—The product has previously been initialized.
- Allocation error—CAIRIM was unable to allocate the product LOADLIB (see message CAS9150E).
- Loadlib open error—CAIRIM was unable to open the product LOADLIB.
- Attach error—A nonzero return code from the z/OS Attach macro occurred while trying to run the initialization routine.
- Init routine RC=nnnn—A nonzero return code or abend occurred within the product initialization routine.
- Initialization abend—There was an abend in the initialization routine, or an error occurred while trying to execute it.
- Internal error—Internal processing error. This should only occur if the status table used to keep track of initialized products is full (this table has room for 64 products).
Action:
Any of these errors cause CAIRIM to terminate processing for the current product and continue with any remaining control statements. See the error descriptions for indication of probable error cause.
Copyright © 2014 CA Technologies.