Previous Topic: Emergency Key GeneratorNext Topic: Activate EKG Using the KEYS Data Set Member


Activate EKG Using the START Command

You can activate EKG using the START command to suppress messages. The START command requires manual intervention.

Follow these steps:

  1. Issue the following console command:
    START CAS9,,,EKGP
    

    The CAS9117A message appears and prompts you for an EKG code.

    Important! You have three attempts at entering a valid EKG code before EKG processing is aborted.

  2. Reply to the message.

    On acceptance of the code, EKG is activated.

Example: Console Display

This example shows the console display when running CAIRIM with the EKGP parameter:

S CAS9,,,EKGP	1
00 CAS9117A ‑ ENTER EKG DEVICE CODE OR CANCEL TO ABORT	2
R 00,1A2B3C4D	3
CAS9116I ‑ EKG DEVICE CODE ACCEPTED ACTIVATED ON:	4
     AUGUST 28, 2008 G.M.T
CAS9115I ‑ INPUT: PROD(L0) CPU(3090‑600 /011111) DATE(28AUG11)
     LMPCODE(XXXXXXXXXXXXXXXX)
CAS9190I ‑ PRODUCT L0 KEY ACCEPTED FOR THIS CPU	5
CAS9115I ‑ INPUT: PROD(SO) CPU(3090‑600 /099999) DATE(28AUG11)
     LMPCODE(YYYYYYYYYYYYYYYY)
1

CAIRIM is started with the EKGP parameter.

2

The operator is prompted for an EKG code.

3

The operator replies.

4

The EKG code is accepted and activated on August 28, 2008 GMT.

5

The execution key for the indicated product is accepted for the CPU, even if the computer type and serial number do not match what is contained in the execution key.