Activate EKG by including a PARM keyword in the EXEC statement of the CAS9 procedure to suppress messages. It requires manual intervention.
Follow these steps:
//CAIRIM EXEC PGM=CAIRIM,PARM=EKGP
The CAS9117A message appears and prompts you for an EKG code.
On acceptance of the code, EKG is activated.
Example: Session Display
This example shows the session when executing CAIRIM with the PARM=EKGP parameter:
00 CAS9117A ‑ ENTER EKG DEVICE CODE OR CANCEL TO ABORT 1
R 00,1A2B3C4D 2
CAS9116I ‑ EKG DEVICE CODE ACCEPTED ACTIVATED ON: 3
AUGUST 28, 2008 G.M.T
CAS9115I ‑ INPUT: PROD(L0) CPU(3090‑600 /011111) DATE(28AUG12)
LMPCODE(XXXXXXXXXXXXXXXX)
CAS9190I ‑ PRODUCT L0 KEY ACCEPTED FOR THIS CPU 4
CAS9115I ‑ INPUT: PROD(SO) CPU(3090‑600 /099999) DATE(28AUG12)
LMPCODE(YYYYYYYYYYYYYYYY)
The operator is prompted for an EKG code.
The operator replies.
The EKG code is accepted and activated on August 28, 2008 GMT.
The execution key for the indicated product is accepted for the CPU, even if the computer type and serial number do not match what is contained in the execution key.
|
Copyright © 2014 CA Technologies.
All rights reserved.
|
|