Previous Topic: MSMD1700-2205Next Topic: MSMD5000-5090


MSMD3000-3010

MSMD3000E

The CAICCI System ID did not match

Reason:

The system name was found in the generated table for CAICCI systems, but the CAICCI system ID did not match the one defined through the CA CSM user interface or multiple systems with the same system name are defined with different CAICCI system IDs.

The CAICCI system ID is a unique name for a system that is part of a CAICCI network. If you do not specify one, CA CSM obtains it using a validate action.

Action:

MSMD3000I

CCI FEEDBACK MESSAGE:

Reason:

This message provides up to a 45-byte CCI feedback message related to the CCI operation performed. This is a general flow message.

Action:

No action is required. This message is informational. However, if you are experiencing problems deploying a product, save and report this message to CA Support.

MSMD3001E

System was not found in the CCI network

Reason:

The system name was not found in the active network.

Actions:

MSMD3001I

Deployment CCI status message

Reason:

This message provides a status for each CCI function executed to perform a deployment.

Action:

No action is required. This message is informational. However, if you are experiencing problems deploying a product, save and report this message to CA Support.

MSMD3002E

Remote validation did not complete

Reason:

An error occurred between the time the remote validation service ended and completion notify process was done with data returned.

Action:

Contact CA Support.

MSMD3002I

DEPLOYMENT TO MSMD-DPL_APPLICATION COMPLETED FOR SNAME

Reason:

Deployment has completed to the system name, SNAME. MSMD-DPL_APPLICATION is the name of the service of the CA CSM Remote Deployment Service in CCS ENF/CCI.

Action:

No action is required. This message is informational.

MSMD3003E

Storage error was encountered

Reason:

This is the Short-on-Storage for the necessary work areas and buffers. This could be a temporary issue or indication of a more serve issue.

Action:

Contact CA Support.

MSMD3004E

CCI error was encountered

Reason:

A CCS CCI API error was encountered during the search operation.

Action:

Contact CA Support.

MSMD3005E

Internal search error was encountered

Reason:

Program MSMDCCII encountered an error while searching for the system name.

Action:

Contact CA Support.

MSMD3006E

Validation Timeout Error was encountered

Reason:

The system will wait four minutes for a response to the system validation command. After that limit, a timeout will occur.

Action:

Retry the validation, and if that does not work, contact CA Support.

MSMD3007E

The Sysplex discovered for system XXXXXXXX was YYYYYYYY, not ZZZZZZZZ.

Reason:

The system validation returned a different Sysplex affiliation for the system where XXXXXXXX is the system name, YYYYYYYY is the name it was defined as, and ZZZZZZZZ was the not the name that was required at validation time.

Action:

Accept the changes or redefine the system.

MSMD3008E

System: XXXXXXXX is currently a Non-Sysplex system

Reason:

The system validation returned that the system is not affiliated with any defined Sysplexes. XXXXXXXX is the system name.

Action:

Delete the system from the Sysplex definition.

MSMD3009E

CCI is not remotely valid

Reason:

This happens during the CCI validation of the remote system when the name of the remote system does not match the target system name on the local system.

The System Registry Validate action did a local inquiry with the given SYSTEM NAME and CCI SYSTEM ID that was unsuccessful.

If only the SYSTEM NAME was entered in the registry, then either the CCI connection between the local and remote system is down, or the SYSTEM NAME is not the correct name.

Action:

Review the task message in the Task Manager, and verify that the name of the remote system matches the target system name on the remote system.

MSMD3009I

MSMDPLOR state

Reason:

Deployment information state flow message.

Action:

No action is required. This message is informational.

MSMD3010E

CCI is not locally valid

Reason:

This happens during the CCI validation of the remote system when the name of the remote system matches the target system name on the local system , but the CCI SYSTEM ID does not match.

The System Registry Validate action did a local inquiry with the given SYSTEM NAME and CCI SYSTEM ID. The inquiry was unsuccessful.

Action: