Previous Topic: Select a Target ZoneNext Topic: Use an Existing Target Zone


Create a Target Zone

You can create a target zone in a new or an existing SMP/E environment where you install your product. The target zone parameters are prepopulated with the values that are entered for the SMP/E environment. You can change data set allocation parameters.

You can specify a different SMP/E environment data set to be used for a new target zone.

Follow these steps:

  1. On the Target Zone step, substep 2, review and specify the following parameters as applicable:
    Target Zone Name

    Defines the name for the target zone.

    Create New CSI Data Set

    Specifies that a new CSI data set will be created for the target zone.

    Data Set Name Prefix

    Defines the prefix for the name of the target zone data set.

    Note: This field is only enabled when you have the Create New CSI Data Set check box selected.

    Catalog

    Defines the name of the SMP/E target zone catalog.

    Note: This field is only enabled when you have the Create New CSI Data Set check box selected.

    Cross-Region

    Identifies the cross-region sharing option for SMP/E data sets.

    Note: This parameter is set to its default value, and you cannot edit it.

    Cross-System

    Identifies the cross-system sharing option for SMP/E data sets.

    Note: This parameter is set to its default value, and you cannot edit it.

    High-Level Qualifier

    Specifies the high-level qualifier (HLQ) for all target zone data sets that are allocated during installation. Product packaging defines the low-level qualifiers (LLQ) and they cannot be changed.

    DSN Type

    Specifies the DSN type for allocating target zone data sets.

    SMS Parameters / Data Set Parameters

    Specifies if this target zone uses SMS or data set parameters.

    Storage Class (SMS Parameters only)

    Defines the SMS storage class for target zone data sets.

    Management Class (SMS Parameters only)

    Defines the management class for target zone data sets.

    Data Class (SMS Parameters only)

    Defines the data class for target zone data sets.

    VOLSER (Data Set Parameters only)

    Defines the volume serial number on which to place data sets. The volume must have enough space for allocating the data sets.

    Note: This field is mandatory if you set Catalog to No.

    Unit (Data Set Parameters only)

    Defines the type of the DASD on which to place data sets.

    Catalog (Data Set Parameters only)

    Specifies if you want SMP/E data set to be cataloged.

    Note: An information text area can appear at the bottom of the wizard. The area provides information that helps you progress through the wizard. For example, if a field is highlighted (indicating an error), the information text area identifies the error.

  2. Click Next.

    A list of the data sets to be created for the target zone appears.