Previous Topic: MIM ProfileNext Topic: VTAM Profile


MVS Profile

This is the MVS environment profile.

This profile has the following environment variables:

SYSRES - MVS system residence volume serial number

Specifies the system residence volume serial number. Enter a 1 to 6 uppercase alphanumeric, national (#,@,$), or hyphen (-) character text string.

PROCLIB - MVS PROCLIB data set name

Specifies the MVS PROCLIB library in the MASTER JCL concatenation. Enter a 1 to 44 character MVS data set name.

PRCLVSER - MVS PROCLIB volume serial number

Specifies the PROCLIB volume serial number. Enter a blank space, or a 1 to 6 uppercase alphanumeric, national (#,@,$), or hyphen (-) character text string.

JESPROC - MVS JESPROC data set name

Specifies the JES procedure library in the JES JCL concatenation. Enter a 1 to 44 character MVS data set name.

JESPVSER - MVS JESPROC volume serial number

Specifies the JESPROC volume serial number. Enter a blank space, or a 1 to 6 uppercase alphanumeric, national (#,@,$), or hyphen (-) character text string.

MCATDSN - MVS master catalog data set name

Specifies the MVS master catalog. Enter a 1 to 44 character MVS data set name.

MCATVSER - MVS master catalog volume serial number

Specifies the master catalog volume serial number. Enter a 1 to 6 uppercase alphanumeric, national (#,@,$), or hyphen (-) character text string.

MACLIB - MVS macro library data set name

Specifies the macro library. Enter a 1 to 44 character MVS data set name.

MODGEN - MVS MODGEN library data set name

Specifies the MODGEN library. Enter a 1 to 44 character MVS data set name.

SCEERUN - MVS LE SCEERUN runtime library data set name

Specifies the MVS Language Environment (LE) dynamic runtime library. Enter a 1 to 44 character MVS data set name.

SCEERUN2 - MVS LE SCEERUN2 runtime library data set name

Specifies the MVS Language Environment (LE) dynamic runtime library. Enter a 1 to 44 character MVS data set name.

SCEEINLL - SCEERUN and SCEERUN2 in the LNKLST/LPALST

Specifies whether the MVS Language Environment (LE) dynamic runtime libraries SCEERUN and SCEERUN2 are in the LNKLST/LPALST. Select one: YES|NO.

SCEEMAC - MVS LE SCEEMAC macro library data set name

Specifies the MVS Language Environment (LE) macro library. Enter a 1 to 44 character MVS data set name.

SCEEOBJ - MVS LE SCEEOBJ object module library data set name

Specifies the MVS Language Environment (LE) object module library. Enter a 1 to 44 character MVS data set name.

SCEELKED - C/C++ non-XPLINK (uppercase, no long name) resident routine library data set name

Specifies the C/C++ non-XPLINK (uppercase, no long name) resident routine library. Enter a 1 to 44 character MVS data set name.

SCEELKEX - C/C++ non-XPLINK (case sensitive, long name) resident routine library data set name

Specifies the C/C++ non-XPLINK (case sensitive, long name) resident routine library. Enter a 1 to 44 character MVS data set name.

SCEELIB - C/C++ non-XPLINK (case sensitive, long name) resident routine library data set name

Specifies the C/C++ XPLINK (uppercase, no long name) resident routine library. Enter a 1 to 44 character MVS data set name.

SCEECPP - C/C++ base definition library data set name

Specifies the C/C++ base definition library. Enter a 1 to 44 character MVS data set name.

SCEECICS - COBOL specific CICS LE runtime library data set name

Specifies the COBOL specific CICS LE runtime library. Enter a 1 to 44 character MVS data set name.

SCEEBND2 - Language Environment (LE) resident routine library data set name

Specifies the Language Environment (LE) resident routine library. Enter a 1 to 44 character MVS data set name.

JESTYPE - Job entry subsystem type

Specifies job entry subsystem type for the system. Select one: JES2|JES3.

ESMTYPE - External security manager type

Specifies external security manager type for the system. Select one: ACF2|TSS|RACF.

LIBRARYTYPE - DSNTYPE for a partitioned data set

Specifies the default library allocation type. Select one: PDS|LIBRARY.

SMFNAME - SMF system identifier

Specifies the SMF system identifier that is used in SMF records. Enter a 1 to 4 character mixed case text string.

SYSPLEX - MVS static symbol for the name of the SYSPLEX

Specifies the value assigned to the MVS static symbol &SYSPLEX. Enter a 1 to 8 character uppercase alphanumeric or national (#,@,$) text string that must begin with an alphabetic or national character.

SYSNAME - MVS static symbol for the name of the system

Specifies the value assigned to the MVS static symbol &SYSNAME. Enter a 1 to 8 character uppercase alphanumeric or national (#,@,$) text string that must begin with an alphabetic or national character.

SYSCLONE - MVS static symbol for shorthand notation of the system name

Specifies the value assigned to the MVS static symbol &SYSCLONE. Enter a 2 character uppercase alphanumeric or national (#,@,$) text string.

SYSR1 - MVS static symbol for the IPL volume serial number

Specifies the value assigned to the MVS static symbol &SYSR1. Enter a 1 to 6 uppercase alphanumeric, national (#,@,$), or hyphen (-) character text string.

SYSALVL - MVS static symbol for the architecture level of the system

Specifies the value assigned to the MVS static symbol &SYSALVL. Enter a 1 digit numeric value.

LFAREA - Amount of real storage used to back large pages

Specifies the amount of real MVS storage used to back 1 MB pages. Enter the string value that is specified for the LFAREA parameter defined in the SYS1.PARMLIB(IEASYSxx) member. Enter NONE, if no LFAREA parameter is specified.