CA Automation Point recognizes a SYSPLEX session by the IEE612I or IEE512I message. The state script puts the console in non-delete mode and formats the messages to include time stamps, session name, and job names. The state script also deletes any existing display areas and issues a message telling CA OPS/MVS that CA Automation Point is active on this console. (See the AXCCOMM application.) CA provides a sample SYSPLEX.scr file with CA Automation Point. For more information on AXCCOM, see the AXCCOMM.txt file.
A message on a SYSPLEX console may look like this:
*09.28.38 X2345678 SYSABC *093 IEF355A INITIATOR TERMINATED, RESTART
When processing this message, CA Automation Point sets the following environmental variables as follows and passes the message to rules for processing:
|
Variable |
Is Set to This Value |
|---|---|
|
&HOSTTIME |
09.28.38 |
|
&JOBNAME |
JOB45678 |
|
&JES3NAME |
SYSABC |
|
&REPLYID |
093 |
|
&MSG |
IEF355A INITIATOR TERMINATED, RESTART |
|
&WORD1 |
IEF355A |
|
&WORD2 |
INITIATOR |
|
&WORD3 |
TERMINATED, |
|
&WORD4 |
RESTART |
|
Copyright © 2012 CA Technologies.
All rights reserved.
|
|