To change the logging parameters that you see when RiskMinder Server starts up:
[arcot/riskfort/startup] LogDir=logs LogFileSize=2097152 BackupLogFileDir=logs/backup LogLevel=2 LogTimeGMT=0 LogTrace=0
The following table provides details about these parameters.
|
Parameter |
Default |
Description |
|---|---|---|
|
LogDir |
logs |
The location of the default log directory. Note: This path is relative to ARCOT_HOME (Windows:<install_location>\Arcot Systems |
|
LogFileSize |
10485760 |
The maximum number of bytes the log file can contain. When a log file reaches this size, a new file is created and the old file is moved to the location specified for BackupLogFileDir. |
|
BackupLogFileDir |
logs/backup |
The location of the directory where backup log files are maintained, after the current file exceeds LogFileSize bytes. Note: This path is relative to ARCOT_HOME (Windows:<install_location>\Arcot Systems |
|
LogLevel |
1 |
The default logging level for the server, unless an override is specified. The possible values are:
|
|
LogTimeGMT |
0 |
The parameter that indicates the time zone of the time stamp in the log files. The possible values are:
|
|