The Device Velocity Check rule keeps a check on the number of transactions from a device within a specified period of time. It is based on the following parameters:
Denotes the number of transaction (M) performed by RiskMinder for a specified device, irrespective of whether the risk evaluation resulted in success or failure.
The default value for this parameter is 10.
Denotes the time period (T) in which the number of transactions are tracked.
The default value for this parameter is 60.
Denotes the unit in which the time period (T) is measured.
The default value for this parameter is Minutes.
To configure the Device Velocity Check rule, perform the following steps:
The Rules and Scoring Management page appears.
The configuration information for the specified ruleset appears.
The RiskFort Rule Builder page appears.
This value denotes the maximum number of transactions (within the specified time interval) that is considered safe for a device. If the actual number of transactions within the specified time exceeds this number, then RiskMinder tracks the transaction as a risk, which results in the matching of the Device Velocity rule.
The changes are not yet active and are not available to your end users.
See "Migrating to Production" for instructions to do so.
See "Refreshing the Cache" for instructions on how to do this.
|