Troubleshooting Tips
If the management console does not display shared data properly, validate the following:
- Within a source set, the same server IP must not be managed by more than one management console. In this case, some of the application data may appear in more than one management console, or all the data may unexpectedly appear in the management console that does not communicate with the Cisco WAE that is closest to the application server.
- The flow filters on the Cisco WAE devices are up-to-date. After you configure a monitor to share data, it can take up to 25 minutes for the monitor to communicate with each shared management console and update the flow filters on the Cisco WAE devices. The list of servers in the flow filters should be the same on all Cisco WAE devices.
- All the monitors that receive packet digests from a Cisco WAE device can communicate with each other on TCP-7878.
- All the monitors that receive packet digests from a Cisco WAE device can communicate with each management console on TCP-3308.
- The same configuration file is on each monitor.