If you notice there are twice the number of expected observations and doubly-long NRTT, you might need to exclude all packets from selected Monitor ports on the CA GigaStor device. The port-blocking feature is an effective way to monitor in multi-tier environments. If you have configured the CA GigaStor so that different ports report the same server traffic from different vantage points, for example, from an access switch and a distribution switch, you can exclude data from the distribution switch so that those packets are not seen as duplicates of packets collected from the access switch.
Follow these steps:
/exclude port=port
Where port is a port value that ranges from zero to 7, which maps to the 1 to 8 range in the CA GigaStor interface. To specify more than one input port on the CA GigaStor, separate each entry with a comma.
|
Copyright © 2014 CA Technologies.