Storage Failure Detection Messages

The following messages are displayed when a problem is detected with the storage of a particular server in the grid:

Message ID

Severity

Message text

Reason

Action

100_srv_server_name

alert

The following devices are not monitored on server server: list of devices

The devices listed are not monitored for storage failure detection process.

No action is required. This message is informational.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, FAILED SMART self-check. BACK UP DATA NOW!. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, Failed SMART usage Attribute: attribute. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, Self-Test Log error count increased from M to N. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, not capable of SMART self-check. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, failed to read SMART Attribute Data. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, unable to open device. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, Read SMART Error Log Failed. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, Read SMART Self-Test Log Failed. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, Temperature num Celsius reached critical limit of num Celsius (Min/Max M/N). See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, ATA error count increased from M to N. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, num Currently unreadable (pending) sectors. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_srv_server_name

alert

Possible storage system failure on Server server. Error: Device: device, num Offline uncorrectable sectors. See recommended actions.

SMART check failed on the server for the device listed. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.

100_comp_server_name

alert

Server 'server name' was disabled on date because it has gone down too often within the specified time period.

A problem with the server was detected. A storage system failure is possible.

(1) Disable the server if not already disabled.
(2) Back the data up immediately and move the volumes to another server.
(3) Contact CA Support for further assistance.