hf7694 is a mandatory hotfix for CA AppLogic® 3.5.19 and 3.5.22. hf7694 resolves the following device support issues.

Note: All bug fixes affect only Xen-based grids unless otherwise noted.

  1. SCR 7516 where NIC state is wrongly reported for Emulex 10G-based NICs
  2. SCR 7528 where Intel e1000e NIC driver hardware hangs

In addition, hf7694 resolves the following grid stability issues:

  1. SCR 7611 resolves several Xen security advisories
  2. SCR 7665 where stopping multiple appliances can overload the server and lead to cleanup failures causing grid instability
  3. SCR 7673 where the Xen netback driver crashes while processing large network packets
  4. SCR 7569 where app stop hangs after applications has been running for more than 10 days (ESX-based grids only)
  5. SCR 7666 where an unnecessary error message is printed when a packet is dropped by a network queue
  6. SCR 6169 where Windows appliances fail to start after the hostname is changed
  7. SCR 7658 where not all of the physical disks of the servers are utilized upon grid creation
  8. SCR 7667 where upon a server reboot Xen leaves behind large files that are never deleted

The resolution to the above SCRs affects grid servers that use any of the following hardware:

  1. Broadcom NetXtreme II 1 Gigabit Ethernet controller chipsets

    BCM5706/BCM5708/5709/5716

  2. Broadcom NetXtreme II 10 Gigabit Ethernet controller chipsets

    BCM57710/BCM57711/BCM57711E/BCM57712

  3. ServerEngines Corp. Emulex OneConnect 10Gb NIC (be3) (rev 01)
  4. Devices supported by Intel e1000e NIC driver

    Intel® 82563 Gigabit Ethernet PHY

    Intel® 82566 Gigabit Ethernet PHY

    Intel® 82567 Gigabit Ethernet Controller

    Intel® 82571EB Gigabit Ethernet Controller

    Intel® 82572EI Gigabit Ethernet Controller

    Intel® 82573E Gigabit Ethernet Controller

    Intel® 82573L Gigabit Ethernet Controller

    Intel® 82573V Gigabit Ethernet Controller

    Intel® 82574 Gigabit Ethernet Controller

    Intel® 82577 Gigabit Ethernet PHY

    Intel® 82578 Gigabit Ethernet PHY

    Intel® 82579 Gigabit Ethernet Controller

    Intel® 82583V Gigabit Ethernet Controller

    Intel® Gigabit CT Desktop Adapter

    Intel® Gigabit PT Quad Port Server ExpressModule

    Intel® PRO/1000 PF Dual Port Server Adapter

    Intel® PRO/1000 PF Quad Port Server Adapter

    Intel® PRO/1000 PF Server Adapter

    Intel® PRO/1000 PT Desktop Adapter

    Intel® PRO/1000 PT Dual Port Server Adapter

    Intel® PRO/1000 PT Quad Port Low Profile Server Adapter

    Intel® PRO/1000 PT Quad Port Server Adapter

    Intel® PRO/1000 PT Server Adapter

  5. Dell PowerEdge RAID Controller (PERC) H200 disk controller
  6. HP DL380 with Smart Array G6 P410i disk controller

This hotfix resolves the following Xen Security Advisories:

  1. XSA-6 HVM e1000, buffer overflow.
  2. XSA-7 64-bit PV guest privilege escalation vulnerability.
  3. XSA-8 Guest denial of service on syscall/sysenter exception generation.
  4. XSA-9 PV guest host Denial of Service.
  5. XSA-11 HVM guest destroy p2m teardown host DoS vulnerability.
  6. XSA-12 Hypercall set_debugreg vulnerability.
  7. XSA-13 Hypercall physdev_get_free_pirq vulnerability.
  8. XSA-14 XENMEM_populate_physmap DoS vulnerability.
  9. XSA-16 PHYSDEVOP_map_pirq index vulnerability.
  10. XSA-17 Qemu VT100 emulation vulnerability.
  11. XSA-19 Guest administrator can access qemu monitor console.

Note: hf7694 includes all previous hotfixes that were released for CA AppLogic® 3.5. hf7694 includes hf7611, hf6169 and hf7516. If the distro hotfix df7588 is installed there is no need of installing hotfix hf7694.

This hotfix is only for CA AppLogic® 3.5.19 and 3.5.22 grids (and may not be used with any other CA AppLogic® version). This hotfix replaces files on the servers of the grid. Therefore, a grid reboot is required after applying this hotfix. If this hotfix is installed on a grid and afterwards a new server is added to the grid, this hotfix is automatically installed on the newly added server, however the newly added server must be rebooted for the hotfix to take effect. If a grid is created and hf7694 is installed during the grid creation process, the grid needs to be rebooted after the grid creation has completed in order for the hotfix to take effect.