Message Descriptions › VAM Messages › VAM0523
VAM0523
DISK QUOTA TABLE LAST STORED WITH PLSQFACT: (variable text); CURRENT VALUE PLSQFACT: (different variable text)
CSA QUOTA TABLE LAST STORED WITH PLSQFACT: (variable text); CURRENT VALUE PLSQFACT: (different variable text)
DISK QUOTA TABLE LAST STORED WITH PLSKBYTE: (packed decimal numeric value); CURRENT VALUE PLSKBYTE: (different packed decimal numeric value)
CSA QUOTA TABLE LAST STORED WITH PLSKBYTE: (packed decimal numeric value); CURRENT VALUE PLSKBYTE: (different packed decimal numeric value)
Reason:
Conflicting PLSQFACT or PLSKBYTE values are preventing the current operation (INSTALL, REFRESH, QREBUILD, or QSYNC) from completing. When changing values of either PLSKBYTE or PLSQFACT, a QREBUILD needs to be done on the subsequent startup to maintain the validity of the quota statistics.
Action:
Two options:
- To resynchronize the PLSKBYTE and PLSQFACT values with the quota allocation statistics, change their values to reflect the current quota allocation statistics.
- To resynchronize the quota allocation statistics with the PLSKBYTE and PLSQFACT values, a QREBUILD is needed.
Copyright © 2015 CA Technologies.