Reason:
This abend is uniquely associated with TMSFORMT. (For more information on this utility, see the Utilities and Reports Reference Guide.) The following reason codes are issued in register 15:
|
Code |
Reason |
Action |
|---|---|---|
|
01 |
Invalid DATEFMT parameter. |
Correct the DATEFMT parameter and resubmit the job. |
|
02 |
CA 1 is not batch active. |
CA 1 must be batch active to perform an EXTEND operation on the TMC. For instructions on using TMSINIT to make CA 1 batch active see the Utilities and Reports Reference Guide. |
|
03 |
An invalid volume serial number not in the TMC was encountered during TMSFORMT processing. |
Check the TMSFORMT output listings for other associated error messages. If either TMSXITU or TMSXITE has been changed, review these changes and correct the logic. |
|
04 |
The number of DSNBs in RESTORE Control Record 2 does not agree with the number of DSNBs read. |
Execute TMSPTRS to identify the errors causing the problem. After correction, resubmit. |
|
05 |
A FORMAT operation was requested without PARM=NEW being specified and CA 1 is not active. |
Either add the PARM=NEW parameter to FORMAT the TMC with CA 1 inactive, or activate CA 1 before resubmitting your job. |
|
06 |
A reply of END was entered in response to the IEFTMS62 WTOR message. |
If the job is to be rerun, correct the TMC dsname and resubmit the job, otherwise no action is needed. |
|
07 |
TMSFORMT is being used to add a range to a TMC that is in the extended format. |
Use TMSXTEND to add a volume range to the TMC. |
|
Copyright © 2013 CA Technologies.