Previous Topic: U1004Next Topic: U1006


U1005

Reason:

This abend is uniquely associated with TMSCOPY. The TMSCOPY output provides more information. For details on the TMSCOPY utility, see the Utilities and Reports Reference Guide. The following reason codes are issued in register 15:

Code

Reason

Action

04

This indicates a bad DSNB record.

Use TMSPTRS to identify the error and then manually correct the bad DSNB record.

08

This indicates a bad TMC record.

Use TMSUPDTE to correct the bad TMC record.

0C

The number of TMC Volume or DSNB records did not match the total number generated in the Control records.

See the report for more specific error information and correct accordingly.

10

CA 1 is not in the proper operating mode to execute a RESTORE operation.

CA 1 must be inactive or batch active. Take the appropriate corrective action.

14

An invalid TMC Volume or DSNB record was encountered during a BACKUP or RESTORE operation.

See the report for more specific error information and correct accordingly.

18

An I/O error occurred while reading a file. The output provides more information.

See the sample TMSCOPY JCL for correct DCB information.

1C

During RESTORE processing, the AUDIT DD was specified as DUMMY.

Even if Audit records are not going to be processed in the RESTORE, a valid formatted Audit must be available to TMSCOPY.

24

During a copy operation, a bad value was detected in control record 5 of a BLOCKSET audit file.

Contact CA 1 Support for assistance in correcting this error.