Reason:
Between the time that TMSVMEDT selected the TMC record and the time that TMSVMUPD attempted the update, the DSN in the record was altered.
Action:
Update the data set name to the proper value. The next execution of the VMS will vault the volume.
Reason:
Between the time that TMSVMEDT selected the TMC record and the time that TMSVMUPD attempted the update, the volume was scratched by TMSCLEAN.
Action:
If the tape needs to be vaulted and has not been overwritten, manually update the volume record to set the correct expiration date (which also removes the scratch status). The next execution of the VMS will vault the volume.
Reason:
Between the time that TMSVMEDT selected the TMC record and the time that TMSVMUPD attempted the update, the outcode was changed.
Action:
No action is required. The volume may be selected upon the next execution of VMS, depending on the vault pattern.
Reason:
The volume serial number of the TMC record is not valid.
Action:
Determine which volume record is in error by examining TMSReport 1 - Volume Serial Number Master produced by the TMEVSNM CA Earl member. Update the VOLSER field to the correct volume serial number.
|
Copyright © 2013 CA Technologies.
All rights reserved.
|
|