Reason:
The tape VOLSER indicated by xxxxxx has been bypassed for initialization.
Action:
Review the report for other messages related to the failure. Correct and resubmit the job.
Reason:
The ACCESS keyword can only be specified if LABTYPE=AL.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
The requested ACCESS value is not blank or A through Z.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
The TMC record for this request cannot be in delete status.
Action:
Update the TMC or correct the control statement(s) and resubmit the job.
Reason:
An error occurred when attempting to write to the TMC or Audit file. Note: Tape has been labeled.
Action:
Review the report for other messages related to the failure. Review the job output and identify failing label requests. Correct the statements and run new label job if necessary.
Reason:
An error occurred when attempting to write a tape label.
Action:
Review the report for other messages related to the failure. Correct the statements and run new label job if necessary.
Reason:
The requested DISP is not one of the supported types.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
A hardware or media failure prevented the mounted tape from being initialized.
Action:
Check the console log for details from either MVS or CA1.
Reason:
The requested LABTYPE is not one of the supported types.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
The requested VOLSER is not in delete status in the TMC.
Action:
Update the TMC or correct the control statement(s) and resubmit the job.
Reason:
The requested VOLSER is not scratch and must be scratch to initialize.
Action:
Update the TMC or correct the control statement(s) and resubmit the job.
Reason:
TMSTPNIT allows NUMBTAPE values of 1 through 255.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
NUMBTAPE requests initializing for the next n tapes in the TMC. OUTTAPE indicates that the tape is not in the TMC; therefore, NUMBTAPE cannot be performed.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
The operator response to the CALOTN01 message differs from the SER input parameter.
Action:
Ensure correct tape is mounted and reply with the correct SER input parameter.
Reason:
The user exit return code is 12.
Action:
Correct and resubmit the job, if necessary.
Reason:
A VOLSER is required for all command verbs.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
The control statement is invalid or contains improperly coded command verbs or keyword parameters
Action:
Correct the control statement(s) and resubmit the job.
Reason:
The tape volume has been successfully initialized. Tape was formerly initialized as vvvvvv. If a plus follows the VOLSER, this indicates that the former VOLSER was that of a foreign tape.
Action:
None. This is an informational message.
Reason:
Processing OUTTAPE and the VOLSER in the tape label is controlled by TMC
Action:
Correct the control statement(s) and resubmit the job.
Reason:
VOLSER must be in delete status for this command.
Action:
Update the TMC or correct the control statement(s)and resubmit the job.
Reason:
The tape requested for INTAPE,OLDTAPE, or NEWTAPE was not found in the TMC when processing NUMBTAPE.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
The VOLSER in the tape label was not in delete or scratch status.
Action:
Update the TMC or correct the control statement(s) and resubmit the job.
Reason:
Unable to write to tape.
Action:
Change write-protect, skip execution or get another tape. Problem may also be caused by insufficient security authorization such as the user ID only having read authority for LABEL=BLP.
Reason:
An OUTTAPE request was unable to write an audit record.
Action:
Correct the problem using the Audit file.
Reason:
The control statement command was not NEWTAPE, OLDTAPE, OUTTAPE or INTAPE.
Action:
Correct the control statement(s) and resubmit the job.
Reason:
NEWTAPE, OLDTAPE or INTAPE was specified but the requested VOLSER is not in the TMC.
Action:
Correct the control statement(s) and resubmit the job.
|