This procedure modifies SYS1.PARMLIB to support CA 1® Tape Management. The SYS1.PARMLIB members to be updated for MVS are:
Specifies the CA common load library (hlq.CTAPLINK ).
Specifies the CA common load library (hlq.CTAPLINK ). This library is not required if in LNKLSTxx and or PROGxx authorized by default.
If you are using a Tape Silo/Robot and your vendor requires exact placement of the CA 1® Tape Management subsystem, then specify subsystem name TMS. Do not specify any other PARMs with TMS.
This specification should also be made if another software automation product modifies tape-related messages or if another software automation product expects to see the TMS prefixed message. The TMS subsystem must be placed ahead of the other product's subsystem entry to help ensure that CA 1® Tape Management properly modifies tape-related mount messages.
If the above does not apply, modification to IEFSSNxx is not necessary. However, CA recommends an explicit entry to prevent possible interference with other products' subsystems. Place the entry near the top of the list. Verify that no subsystem named TLMS is present ahead of TMS.
Specifies the members modified.
Must be active. However, there are no requirements regarding SMF record types that must be recorded.
Add the program names TMSIOCAP and TMSSCR to the AUTHPGM and AUTHTSF entries.
Note: If using the TSO table CSECTs, add the program names to the IKJEFTE2, IKJEFTE8, and IKJEFTAP CSECTs.
|