Use the following formula to calculate the Tape Management Catalog (TMC) storage requirements:
Cylinders = (3 + V + (D / 2)) / RC
The number of volume records.
The number of DSNB records.
The records per cylinder for device type and blocking factor.
Note: Round up all values.
Example: TMC Storage Requirement
In this example, the values are 100,000 Volume records + 300,000 DSNB records (3380):
(3+100,000) + (300,000 / 2)) / 855 = 293 cylinders
|