Calculate Tape Management Catalog Storage Requirements

Use the following formula to calculate the Tape Management Catalog (TMC) storage requirements:

Cylinders = (3 + V + (D / 2)) / RC
V

The number of volume records.

D

The number of DSNB records.

RC

The records per cylinder for device type and blocking factor.

Note: Round up all values.

Example: TMC Storage Requirement

In this example, the values are 100,000 Volume records + 300,000 DSNB records (3380):