Error 15058

Failed to get tape free buffer

Module:

Data Multiplexing

Reason:

BrightStor ARCserve Backup was unable to get enough free Tape drive buffers because there is not enough memory for tape buffers.

Action:

Check server memory. To do so, follow these steps:

  1. Enter LOAD MONITOR from the server console.
  2. Select Resource Utilization from the Available Options menu.
  3. If the cache buffer percentage is very low (below 30%), your server is probably low on memory.
  4. To free memory, unload any NLMs that are not required.
  5. Enter ASTOP from the server console to stop BrightStor ARCserve Backup.
  6. Enter ASTART from the server console to restart BrightStor ARCserve Backup.

If you receive this error again, restart the file server. In addition, consider purchasing more memory for the file server.


© 2005 Computer Associates International, Inc. All rights reserved.