The following table lists return codes and error messages for the DUPMDISK command:
|
Return Code |
Message Number |
Text |
|---|---|---|
|
2 |
0127E |
USER userid1 EXCEEDED USER userid2 type PASSWORD LIMIT [FOR vaddr] |
|
4 |
0038E |
MISSING PARAMETER |
|
6 |
0531E |
PARAMETER userid IS TOO LONG |
|
8 |
0265E |
NOT AUTHORIZED FOR authorization words |
|
10 |
0349E |
PASSWORD IS INCORRECT |
|
12 |
0080E |
USER userid DOES NOT EXIST |
|
14 |
0632E |
MANAGER mgrid WAS NOT FOUND IN THE MANAGERS FILE |
|
16 |
0040E |
TOTAL ALLOCATION LIMIT OF number EXCEEDED |
|
18 |
0632E |
MANAGER mgrid WAS NOT FOUND IN THE MANAGERS FILE |
|
20 |
0382E |
USER userid IS ON HOLD |
|
22 |
0621E |
UNEXPECTED RETURN CODE code FROM OPEN |
|
23 |
0304E |
ADDRESS vaddr IS AN INVALID DEVICE ADDRESS |
|
25 |
0531E |
PARAMETER vaddr IS TOO LONG |
|
26 |
0313E |
DEVICE device DOES NOT EXIST |
|
27 |
0549E |
DEVICE device ALREADY EXISTS |
|
28 |
0634E |
DIRECTORY PROFILE LINKS ALREADY EXIST FOR DEVICE device |
|
30 |
none |
non‑zero return code from DIRECT_PRFLINKS |
|
32 |
0635E |
YOU ARE NOT A MANAGER AND HAVE NO SUBPOOLS THAT YOU ARE AUTHORIZED TO USE |
|
33 |
0636E |
ANYPOOL AUTHORIZATION IS REQUIRED TO ALLOCATE FROM SUBPOOL subpool |
|
34 |
0637E |
THE MINIDISK SIZE size MUST BE AN INTEGER NO LONGER THAN 7 DIGITS |
|
35 |
0043E |
SUBPOOL subpool IS UNDEFINED |
|
36 |
0638E |
A MINIDISK SIZE OF 0 IS NOT ALLOWED |
|
37 |
0831E |
Userid1 vaddr1 AND userid2 vaddr2 MUST HAVE MATCHING SIZE AND DEVICE TYPE. |
|
38 |
0547E |
INVALID DEVICE TYPE devtype (not found in table) |
|
39 |
0119E |
VOLUME ‘volser’ IS NOT A devtype DEVICE |
|
40 |
0547E |
INVALID DEVICE TYPE devtype (not CKD or FBA type) |
|
41 |
0639E |
YOU ARE NOT AUTHORIZED TO ADD A CACHE’d DEVICE |
|
42 |
0640E |
THE parm PARAMETER MAY NOT BE SPECIFIED FOR A MINIDISK ON DEVNO |
|
44 |
0531E |
PARAMETER volser IS TOO LONG |
|
52 |
0637E |
THE MINIDISK SIZE size MUST BE AN INTEGER NO LONGER THAN 7 DIGITS |
|
54 |
0574E |
CANNOT SPECIFY MINIDISK LOCATION WITHOUT VOLSER |
|
58 |
0640E |
THE MODE PARAMETER MAY NOT BE SPECIFIED FOR A MINIDISK ON T‑DISK | V‑DISK |
|
60 |
0642E |
THE SPECIFIED LINK MODE mode IS INVALID |
|
61 |
0531E |
PARAMETER password IS TOO LONG |
|
62 |
0640E |
THE PASSWORD PARAMETER MAY NOT BE SPECIFIED FOR A MINIDISK ON T‑DISK | V‑DISK |
|
65 |
0625E |
TOO MANY SERVANTS IN USE, COMMAND CANNOT BE EXECUTED |
|
66 |
none |
non‑zero return code from DIRECT_QALLOC |
|
67 (CA VM:Secure only) |
none |
non‑zero return code from PENCRYPT |
|
68 |
0643E |
EXTRA PARAMETERS parameters WERE ENTERED AND ARE NOT ALLOWED |
|
69 |
0586E |
ERROR STARTING SERVANT |
|
70 |
0644E |
NOWAIT OPTION SPECIFIED BUT THE SERVANT FACILITY IS NOT ACTIVE |
|
71 |
0648E |
THE NOWAIT OPTION MAY NOT BE SPECIFIED WITH THE STACK OR FILE OPTIONS |
|
76 |
0018E |
INVALID OPTION option |
|
77 |
0698E |
THE option OPTION MAY NOT BE SPECIFIED WITH THE option OPTION |
|
78 |
0647E |
THE WAIT AND FORMAT OPTIONS MAY NOT BE SPECIFIED FOR A MINIDISK ON T‑DISK |
|
79 |
0076S |
USER ERROR ‘nnn’ COPYING FILE ‘fileid’ |
|
80 |
0364E |
FILE filename filetype IS BEING UPDATED |
|
81 |
0220E |
INVALID option OPTION OPERAND parameter |
|
82 |
0617E |
DDR FAILED WITH RC= code WHILE ATTEMPTING TO MOVE THE vaddr1 DISK |
|
88 |
none |
non‑zero return code from DIRECT_OBTAIN |
|
90 |
0209E |
BLOCKSIZE 800 IS NOT SUPPORTED ON FB‑512 DEVICES |
|
91 |
0209E |
BLOCKSIZE 800 IS NOT SUPPORTED ON FB‑512 DEVICES |
|
95 |
none |
non‑zero return code from DIRECT UPDATE |
|
96 |
none |
non‑zero return code from MAN000S0 |
|
98 |
none |
non‑zero return code from MAN000R0 |
|
103 |
0383I |
FROM EXIT: exit message |
|
1nnn |
0200E |
UNEXPECTED ERROR ‘nnn’ LINKING USER ‘userid’ MINIDISK ‘vaddr’ |
|
-231 |
0726E |
SERVANT ABENDED DURING command COMMAND. DIRECTORY NOT CHANGED |
Note:
| Copyright © 2011 CA. All rights reserved. | Tell Technical Publications how we can improve this information |