Previous Topic: Task KVC0I079—Generate CP Nucleus

Next Topic: Examples

Procedure for Panel KVC0I085

To rebuild your current CP nucleus with panel KVC0I085:

  1. Disconnect or use another terminal to complete the following steps.
  2. Log on to your CP system maintenance machine.
  3. Perform any IBM required steps prior to VMFBLD. Examples of what might be needed are VMFSETUP and VMFPF EXECs.
  4. For TEST module generation, link to and access CAIMAINT virtual machine’s 291 disk. For PRODUCTION module generation, link to and access CAIMAINT virtual machine’s 391 and 322 disks.
  5. Generate the CP nucleus module using the supplied CAXABLD EXEC to prefix the standard VMFBLD EXEC.
  6. By default the CP module are placed on the 493 disk and must be moved to the CP parameter disk CF1. Both 493 and CF1 are defaults only and may be redefined by your system.
  7. Save the CP LOAD map and the CAXALOAD SUMMARY A1. CA Top Secret for z/VM support may need this information to debug problems.