The Formatted Trace Table screen enables you to view complete or filtered CICS trace table entries for the dump. You can display trace entries in Abbreviated (default), Short, or Full mode. The presentation of the trace is identical for traces that are within a transaction dump, or those captured using the SYMT trace capture facility.
The trace display starts with the first line of the captured trace. You are able to quickly navigate to where you want to in the trace by using the filter and command line features.
To display the Formatted Trace Table, select Trace under the Formatted Display category on the Display Selection menu.
The trace entries are formatted using DFHTUXX0, for the corresponding release of CICS. For help in interpreting the trace entries, see the appropriate IBM documentation.
The following sample screen shows the CA SymDump for CICS Trace, in Abbreviated Mode:
-------------- CA SymDump for CICS V9.0 FORMATTED TRACE TABLE -------------- COMMAND ===> MODE: A SCROLL: PAGE 000047 00031 QR PG 0901 PGPG ENTRY INITIAL_LINK ASMDEMO 000048 00031 QR LD 0001 LDLD ENTRY ACQUIRE_PROGRAM 200E0AF8 000049 00031 QR LD 0002 LDLD EXIT ACQUIRE_PROGRAM/OK A0D11230,20D11230,2C88,0,REUSABLE,ESDSA,OLD_COPY 000050 00031 QR AP 1940 APLI ENTRY START_PROGRAM ASMDEMO,CEDF,FULLAPI,EXEC,NO,200431C0,00000000 , 00000000,1,NO 000051 00031 QR SM 0C01 SMMG ENTRY GETMAIN 367,YES,00,TASK 000052 00031 QR SM 0C02 SMMG EXIT GETMAIN/OK 00140478 000053 00031 QR AP 00E1 EIP ENTRY HANDLE-CONDITION 0004,00140488 ...h,08000204 .... 000054 00031 QR PG 0700 PGHM ENTRY SET_CONDITIONS 20D13BCD,20D13BCA,001404F4,00140488,ASSEMBLER,80,AMODE31 000055 00031 QR PG 0701 PGHM EXIT SET_CONDITIONS/OK 0 000056 00031 QR AP 00E1 EIP EXIT HANDLE-CONDITION OK 00F4,00000000 ....,00000204 .... 000057 00031 QR AP 00E1 EIP ENTRY READQ-TS 0004,00140488 ...h,08000A04 .... 000058 00031 QR TS 0C01 TSMB ENTRY MATCH DEMAU052 000059 00031 QR TS 0C02 TSMB EXIT MATCH/OK ,,,DEMAU052,,00000000,,ANY,NO,NO 000060 00031 QR TS 0201 TSQR ENTRY READ_INTO DEMAU052,00140610 , 00000000 , 00000024,1,EXEC 000061 00031 QR TS 0202 TSQR EXIT READ_INTO/OK 00140610 , 00000024 , 00000024,1,NO 000062 00031 QR AP 00E1 EIP EXIT READQ-TS OK 00F4,00000000 ....,00000A04 .... 000063 00031 QR AP 1942 APLI *EXC* Program-Check START_PROGRAM,ASMDEMO,CEDF,FULLAPI,EXEC,NO,200431C0,00000000 , 000000 000064 00031 QR AP 0790 SRP *EXC* PROGRAM_CHECK 000065 00031 QR DS 0010 DSBR ENTRY INQUIRE_TASK 000066 00031 QR DS 0011 DSBR EXIT INQUIRE_TASK/OK ESSENTIAL_YES 000067 00031 QR DS 0002 DSAT ENTRY CHANGE_MODE QR PF1 Help 2 3 End 4 Mask 5 Repeat 6 Return On PF7 Backward 8 Forward 9 All Trace 10 Left 11 Right 12 Retrieve
PFKEYS PF key assignments for the trace display follow.
Invoke CA SymDump for CICS HELP facility for this function
No function.
End the Formatted Trace Display. Of special note here, is that when selecting a trace from within a transaction dump, that all trace filters, highlights, and overrides will remain in effect until the dump selection is left completely. Merely leaving the trace selection does not reset these values. For traces captured via the SYMT trace capture facility, all filters, highlights, and overrides are reset when the trace is left.
Display the current Filter Selection Mask.
Repeat Find Command.
Toggle to turn Return Entry display off or on.
Page back by scroll amount.
Page forward by scroll amount.
Toggle to turn filtering on/off.
Scroll left by scroll amount.
Scroll right by scroll amount.
Retrieve previously entered commands.
Command Line: (Top of screen)
Display trace in abbreviated mode.
Display trace in short mode if available.
Display trace in full mode.
Display only trace entries that have line overrides.
Display only trace entries that are highlighted.
Find the next occurrence of a string in the trace (string may be in single or double quotes).
Finds the first occurrence of the string.
Finds the next occurrence.
Command Line: (Top of screen continued)
Finds the last occurrence.
Finds the previous occurrence.
Find the next occurrence of a highlighted entry (sub operands first, next, and so on, same as normal find).
Highlight all occurrences of a string.
Positions trace display to beginning of displayed entries.
Positions trace display to the end of the displayed entries.
Positions trace to a specific line number.
Reset all line overrides.
Reset all highlighted entries to normal intensity.
In conjunction with PF7, PF8, PF10, PF11 scrolling by the specified number of lines.
Line Entry Commands: (Left side of screen)
Entry always displays as abbreviated.
Entry always displays as short if available.
Entry always displays as full.
Entry always displays as highlighted.
Highlight status of entry is reset to normal intensity.
Mode override is reset to default mode.
Mode Setting: (Top of screen on right)
Display entire trace in Abbreviated Mode.
Display entire trace in Short Mode (if available).
Display entire trace in Full Mode.
Display only entries that are set to Highlight status.
Display only entries that are set to Override status.
Scroll Setting: (Top of screen on right)
Scrolling is one page at a time.
Scrolling is for the specified number.
| Copyright © 2011 CA. All rights reserved. | Tell Technical Publications how we can improve this information |