Agent Guides › Web Agent Guide › Troubleshooting › Web Agent Redirects Authenticated Users Back to FCC Login Form
Web Agent Redirects Authenticated Users Back to FCC Login Form
Valid on an IBM HTTP web server running on the Z/OS operating system
Symptom:
When I use an HTML authentication scheme, users are sent back to the login form after entering their credentials.
Solution:
Make the following changes to the configuration of your Web Agent:
- Set the value of the TargetAsRelativeURI parameter to no.
- Set the value of the CookieProvider parameter to the URL of the web server (the same web server that runs the Web Agent).
More information:
Use a Relative Target for Credential Collector Redirects
Specify the Cookie Provider