Previous Topic: Plot the Variable Value for a Specified Resource

Next Topic: SCALE Operand-Change the Scale of a PLOT Report

ALONE Operand—Exclude Global Values from a Plot

Use the ALONE operand to plot the activity of one or more identifiers without including a plot of global activity in the report.

Suppose you want to plot the response time for 0A terminals, but you do not want to plot the average response time for all terminals. You can use the same commands as in the previous example but add the ALONE operand, as follows:

PLOT TERM RESP TERMID(0A*) ALONE
  FROM 12/07/08 01:00:00
  TO   12/07/08 09:00:00
  EACH HOUR
END
RUN

A report like the following is generated:

SHIFT NONE EACH HOUR TERMINAL AVERAGE RESPONSE TIME PERIOD NONE 0 0.033 0.066 0.100 0.133 0.166 0.199 0.232 0.266 0.299 0.332 X +.........+.........+.........+.........+.........+.........+.........+.........+.........+.........+ 12/07/08 01.00.00 .XXXXXXXXXXXX . . . . . . . . . 0.040 02.00.00 .XXXXXXXXXXXXXXXXXXXXXXXXXXX . . . . . . . . 0.090 03.00.00 .XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX . . . . . . . 0.125 04.00.00 .XXXXXXXXXXXXXXXXXXXXXXXXX . . . . . . . . 0.083 05.00.00 .XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX . . . . . . . 0.104 06.00.00 .XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX 0.332 07.00.00 .XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX . . . . . 0.194 08.00.00 .XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX . . . 0.240 SUMMARY: . . . . . . . . . . . SUMMARY: RANGE: .XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX . . . . . . 0.151 +.........+.........+.........+.........+.........+.........+.........+.........+.........+.........+ 0 0.033 0.066 0.100 0.133 0.166 0.199 0.232 0.266 0.299 0.332 X SYMBOLS: “X” = TERMINAL AVERAGE RESPONSE TIME