The STOP_EVENT function stops the recording of elapsed time for any generic event.
Pair this STOP_EVENT request with the START_EVENT request to stop the timing of the event.
Use the following CICS command level program example to code this function:
....+....1....+....2....+....3....+....4....+....5....+....6||7..
DFHEISTG DSECT ,
MEIC GSVCMEI GEN_COMMAREA,DSECT=NO
module DFHEIENT
MVC MEIC_Function,=AL4(MEIC_StopEvent) Function
MVC MEIC_F007_Name,=CL16'eventname' name
MVC MEIC_F007_Type,=CL16'eventtype' type
EXEC CICS LINK PROGRAM('GSVCMEI') X
COMMAREA(MEIC) X
LENGTH(=AL2(MEIC_L))
EXEC CICS RETURN
STOP_EVENT parameters:
Specify a 16-character event name. The event name must be the same as the event name used in the START_EVENT function call corresponding to the STOP_EVENT function call.
Specify a 16-character event type.